Meaning of Each Fuse on the FANUC ROBODRILL I/O Distribution Panel

Fuse Symbol Part Number Rating
FU1 / FU4 A60L-0001-0046#5.0 5.0A
FU2 / FU5 A60L-0001-0046#3.2 3.2A
FU3 A60L-0001-0046#2.0 2.0A
FU6 A60L-0001-0046#1.0 1.0A

Functions of Each Fuse on the I/O Distribution Panel

FU1 (+24A)
Purpose: Power supply protection for the CNC unit and I/O modules.

FU2 (+24B)
Purpose: Protection of input/output signals for ROBODRILL I/O modules.

FU3 (+24C)
Purpose: Protection of the operator panel unit.

FU4 (+24D)
Purpose: Protection for the internal lamp, status indicator lights, and Z-axis brake.

FU5 (+24E)
Purpose: Protection for external interfaces.

FU6 (+24S)
Purpose: Protection for the standby circuit.

  • Before replacing a fuse, you should first identify and eliminate the cause of the fuse blowout.
  • The fuse on the distribution panel’s printed circuit board has a small window that displays a white mark when the fuse blows.

Meaning of Each Fuse on the I/O Board

blog fuse explain

Explanation of the Functions of Each Fuse on the Wiring PCB

FU4 (+24A)

Purpose: Used to protect the power supply for the machine tool’s ON/OFF control.

Symptom: The CNC power supply cannot be turned on.

Solution: Inspect the power ON/OFF circuit on the wiring board. Inspect the cables between the operator panel and the wiring board.

FU5 (+24B)

Purpose: Provides general protection for standard option input/output signals.

Symptom: Standard option input/output signals are not being generated.

Solution: Disconnect the standard option wiring and inspect each individual wire.

FU6 (+24E)

Purpose: Provides protection for the external interface power supply.

Symptom: Alarms EX1012, EX1021, EX1023, EX1024, SV401, SV480, and SV487 occur simultaneously.

Solution: Disconnect the external machine wiring, locate the short circuit, and replace the component.

FU7 (+24C)

Purpose: Protects the operator panel power supply.

Symptom: The CNC power supply is cut off.

Solution: Inspect the keyboard, I/O board, and wiring. Replace the keyboard.

blog
blog FU
FU8 (+24D)

Purpose: Provides protection for the internal light, status indicator lights, and Z-axis brake.

Symptoms: Power to the internal light and status indicator lights is cut off. The Y-axis brake cannot be released.

Solution: Disconnect the wiring for the Y-axis brake, then inspect the brake and wiring.

Connection Targets: XS12-1 Z-axis brake; XS12-2 Machine interior light; XS12-3, 4, 5, 6 Status indicator lights.

Leave a Reply